快(kuai)速(su)(su)動(dong)力(li)學停(ting)流裝置(zhi)與光譜儀器配合(he)進(jin)行快(kuai)速(su)(su)動(dong)力(li)學瞬間實時記錄,或離線分析,為廣大的快(kuai)速(su)(su)動(dong)力(li)學研(yan)究(jiu)學者提(ti)供了強有力(li)的武器。選擇不(bu)同的配置(zhi)可進(jin)行下列應(ying)用:
* 蛋白質折疊動力學(xue)(Protein Folding)
* 酶動力(li)學(Enzyme Kinetice)
* 底物結(jie)合(he)(Substrate Binding)
* 構象(xiang)轉變(Conformational Changes)
* 胞(bao)內(nei)底物運輸(Substrate Transport in Vesicles)
* 第二信(xin)使研究(Second Messenger Studies)
* 快速(su)化學反應動(dong)力學(Rapid Chemical Reaction Kinetics)
KinTek has always been a leader in building stopped-flow instruments that conserve precious samples. The all new AutoSF-120 sets a new standard for sample economy, requiring only 120 microliters of sample to flush, load and collect data, while giving with 3-4 replicate measurements. The flushing and sample loading are all done automatically. Simply pipette 120 microliters of solution into each sample cup and click "Load".
In the process of designing this new state-of-the-art instrument, we also added new noise reduction electronic circuits to improve signal:noise twofold and achieved a submillisecond dead time. In addition we completely re-wrote the system software for data collection and analysis to give unparalleled ease of use and power.
The KinTek AutoSF is by far the best stopped-flow instrument ever built, giving you more high quality data while consuming less sample and less time.
An optional robotic autosampler increases throughput even more to afford unattended stopped-flow measurements of hundreds of samples per day.
技術參數:
1.注射器數量:3個
2.驅動方式:每一個注射器由一個步進馬達驅動
3.最小死時間:0.6毫秒(FC-08池)0.25毫秒(微量池)
4.注射流量范圍:0.01-10ml/s(取決于安裝的注射器)
5.混合比例范圍:1/1至1/100連續可調
主要特點:
1.恒溫水(shui)夾(jia)套設計,全電腦控(kong)制(zhi)操作
2.程控驅(qu)動(dong)注(zhu)射器,每路樣品流量(liang)可調,不受濃度與粘度影(ying)響
3.高精度,完全可調的(de)混(hun)合(he)與稀(xi)釋比例
4.極短的死時間,最短為0.25毫秒
5.二路(lu)、三路(lu)、四路(lu)流動注射停流裝置(zhi)可選(xuan)擇
Small sample volume: 120 μL is sufficient to flush and load a new sample and get 3-4 reproducible shots. All other instruments require 3-5 times as much sample.
Automated computer-controlled load/flush/fire cycle — simply pipet 120 μL into each sample cup and click "load".
Twofold improvement in signal/noise with new noise reduction circuits
Compact footprint: instrument and electronics combined (14 × 26.5 × 4.5 inches)
Computer optimized optical path with lower noise and background fluorescence
Automated sample loader, which can be interfaced with an optional robot.
200 μl of sample is sufficient to load and collect 6-8 good shots.
Standard 10 μl flow cell.
20 μl per shot per solution.
Has two fluorescence channels and one absorbance channel that can be observed and recorded simultaneously.
Under complete computer control, courtesy of the KinTek StopFlow Software.
4TRZ